Hot Metal Detectors MSE-HMD84 Description Technical Info Housing Info Data Sheet Request More Info

The following is specifications and dimensional information on the housing for the MSE-HMD84 Low Temperature Self Contained "All-in-One" Digital Hot Metal Detector.

 

The self-contained MSE-HMD84 Digital Hot Metal Detector in operation at a Hot Strip Mill.

Rear View of the self-contained MSE-HMD84 Low Temperature Digital Hot Metal Detector showing the LED Bar Display, the Setting Switched, The circular Electrical Connector and the, Water/Air Inlet and Outlets.

The MSE-HMD84 Hot Metal Detector's electronic circuitry is packaged in a robust cast aluminum housing. The housing includes a large cooling chamber which is separated from the electronic circuitry compartment. As standard, a sealed water coolant radiator is provided. The copper water coolant radiator is mounted internal to the air cooled chamber. Coolant inlet and outlet fittings are provided in the rear of the cast aluminum housing. An air purge inlet is fitted in the front nozzle of the housing and air is vented out the front of the nozzle in front of the lens providing positive pressure too help keep the lens clean.

An an option an air purge inlet is located in the rear of the cast aluminum housing. Pressurized air passes though the cooling chamber, cooling the cast aluminum housing thus cooling the electronic circuitry. The air vents in the front of the housing via a slot in front of the lens providing air purging.

Further cooling of the air can be accomplished with the use of an in-line vortex tube air cooler. 

For severe environments an additional air purge nozzle can be fitted onto the front of the  MSE-HMD84 housing. The air purge nozzle is constructed of stainless steel for long life and hinged for easy cleaning of the lens. This air purge nozzle is used to further direct the air purge and increase the pressure to clear steam and particulate from the lens. The construction allows for easy attachment to the cast housing with only an Allen wrench. It has an extra tubing fitting if additional air purge is required in severe environments.

   
An MSE-BCT-01 Extension Tube mounted on a MSE-HMD84 Digital Hot Metal Detector

An MSE-BCST-01 Extension Tube mounted on a MSE-HMD84 Digital Hot Metal Detector is used to help decrease background IR.

 

 

Accessory

For applications were it is necessary to decrease background IR an MSE-BCST-01 Extension Tube can be fitted on  onto the front of the  MSE-HMD84 housing. The Extension Tube is constructed of stainless steel for long life and hinged for easy cleaning of the lens. The extension tube is 150 mm in length. The construction allows for easy attachment to the cast housing with an Allen wrench and a Phillips head screwdriver..

   
 
 

Housing Specifications

Housing
Aluminum AL6, Oven baked blue powder coat
Housing Rating
IEC IP66, DIN, 89011
Weight
without Cable: 2.5 Kg (5.5 lbs)
Electrical Box Connector
Circular, Plug/Socket, 16 Pin, Rated: IP66
Cable Length
2 m (6.6ft) standard. Also available in optional lengths of 5 m (16.4ft), 10 m (32.8ft), and 15m (49.2ft)
Cooling: Standard
Standard: -D Water cooled & Air Purged; Optional: -A Air Cooled & Air Purged
 
Housing Dimensions
MSE-HMD84 Low Temperature Digital Hot Metal Detector Housing Dimensional Imformation

Air & Optional Water Specifications

Air Pressure
For Air Purge: < 0.3 Bar  (<4 PSI) for normal conditions.
For Air Cooling: 1 to 3 Bar (14.5 to 43.5 PSI) for very severe conditions. You can use non-instrument dry air
Water Pressure
0.3 to 1 (4.4 to 14.5 PSI), Bar 3 Bar maximum (43.5 PSI)
Water Volume
Regulate between 1 - 2 liters per minute (0.26 - 0.53 gallons per minute)
For Ambient Temperature ≤ 70°C (158°F):  1 liter per minute (0.26 gallons per minute)
For Ambient Temperature < 80°C (176°F):  2 liter per minute (0.53 gallons per minute)
Water Temperature
For Ambient Temperature ≤ 70°C (158°F) use industrial quality water below ≤ 20°C (68°F)
For Ambient Temperature ≤ 80°C (176°F) use water chilled to ≤ 10°C (50°F)

Electrical Terminal Connections

Terminal Connections
Pin No.
Wire Color
Function
1
Pink
Self Check to + 24 VDC Supply
2
Red
 +24 VDC Supply
3
Black
80-240 VAC Supply (L1)
4
White
Supply Neutral (L2)
5
Violet
PNP Transistor Output (#2)
6
Bluet
0 VDC (For 24 VDC Supply
7
Green
Ground
8
Brown
Cradle Relay Output (#1) N.O. Contact
9
Orange or Grey Pink
Cradle Relay Output (#1) N.O. Contact
10
Light Blue or Red/Blue
NPN Transistor Output (#3)
11
Yellow
Optional Reed Relay Output (#4) N.O. Contact
12
Grey
Optional Reed Relay Output (#4) N.O. Contact
 
 