Hot Metal Detectors MSE-RT20 Description Technical Info Housing Info Data Sheet Request More Info

The following is specifications and dimensional information on the housing for the MSE-RT20Cold and Hot Metal Detector Retro-Reflective Laser Barrier.

 
MSE-RT20 Cold and Hot Metal Detector  Retro-Reflective Laser Barrier

The MSE-RT20  Cold and Hot Metal Detector Retro-Reflective Laser Barrier's electronic circuitry is packaged in a robust cast aluminum housing. The housing includes a large air cooled chamber which is separated from the electronic circuitry compartment. An air purge inlet is located in the rear of the cast aluminum housing. Pressurized air passes though this chamber, cooling the cast aluminum housing thus cooling the electronic circuitry. The air vents in the front of the housing via a slot in front of the lens providing air purging. Further cooling of the air can be accomplished with the use of an in-line vortex tube air cooler. 

As an option, a sealed water coolant radiator & separate air purging facility can be provided. The copper water coolant radiator is mounted internal to the air cooled chamber. Coolant inlet and outlet fittings are provided in the rear of the cast aluminum housing. An air inlet is fitted in the front nozzle of the housing and air is vented out the front of the nozzle in front of the lens.

The MSE-RT20  is a direct replacement for the MCSL Model LT200M. Please contact us for additional information.

 

Housing Specifications

Housing
Aluminum AL6, Oven baked blue powder coat
Housing Rating
IEC IP66, DIN, 89011
Weight
without Cable: 2.5 Kg (5.5 lbs)
Electrical Box Connector
Circular, Plug/Socket, 16 Pin, Rated: IP66
Cable Length
2 m (6.6ft) standard. Also available in optional lengths of 5 m (16.4ft), 10 m (32.8ft), and 15m (49.2ft)
Cooling: Standard
Standard: -D Water cooled & Air Purged; Optional: -A Air Cooled & Air Purged





Housing Dimensions
MSE-RT20 Cold and Hot Metal Detector Retro-Reflective Laser Barrier.

Air & Optional Water Specifications

Air Pressure
1-2 cu ft./min at 5 PSI for normal conditions, non-instrument dry air and 10 - 15 PSI for severe conditions
Water Pressure
1 - 2 Bar
Water Volume
Regulate between 0.5 - 1 liter/min.
Water Temperature
For Ambient Temperature up to +80°C (176°F) use industrial quality water below 20°C (68°F)
For Ambient Temperature above +80°C (176°F) use water chilled to 5°C (41°F)

 


Electrical Terminal Connections

Terminal Connections
Pin No.
Wire Color
Function
1
Red
+ 24 VDC Supply
2
Black
0 VDC Supply
3
Green
Shield/Ground
4
Pink
N.C. Relay Output
5
White
Relay Common Output
6
Grey
N.O. Relay Output
7
Yellow
PNP Transistor Output
8
Violet
NPN Transistor Output
9
 
No Connection
10
 
No Connection
11
 
No Connection
12
Brown
Not Used
 

The MSE-RT20  is a direct replacement for the MCSL Model LT200M. Please contact us for additional information.

 