MSE-FMD95 Remote Fiber Digital Hot Metal Detector (HMD
Hot Metal Detectors MSE-FMD95 Description Technical Info Housing Info Data Sheet Request More Info
MSE-FMD95 Fiber Digital Remote Hot Metal Detector shown with switch cover removed.
 

The MSE-FMD95 Fiber Digital Remote Hot Metal Detector shown removed the protective mounting cradle and with programming switch cover removed exposing the upper and lower programming switches.

 
 

Threshold Settings: To accommodate variation in bar temperature and background IR, various precise threshold are programmable via covered switches from 270°C to 1,000°C ( 518°F to 1832°F) to ensure reliable switching with reference to both the displayed background and product IR signal. The trip level is set as fine adjustment and coarse adjustments. 9 levels of fine adjustments which correspond to unit trip points.10 levels of coarse adjustments which correspond to times ten trip points. The trip level span has a 0-109 scale allowing adjustment of the threshold trip level from 270-1000 degrees, this means, every trip unit level has a value of: (1000-270) /109 = 6.7℃.

Background Temperature: High background temperatures decrease the sensitivity of the Hot Metal Detector. This should be not a problem for MSE-FMD95 because it has a Processor controlled function to eliminate this effect. The threshold of the sensor is constantly adjusted during operation according to the background temperature. Thus the best value of threshold is adjusted automatically.

Response Time: The response time of theMSE-HMD85 is programmable from 1ms to 250ms to accommodate black spots on the bar.

Self-Check Facility: The MSE-HMD85 incorporates a remote self-check facility remotely energized by closed contacts that illuminates an internal IR LED to switch the detector and verify the' outputs are operating correctly. This facility allows the user to check the integrity of the optic head, lead, processor, electrical circuit and the signal connection in one operation.

Supply Voltage: The MSE-FMD95 will operate from either 24VDC or optional 80-240 VAC power input with a power consumption of 2 watts.

Hot Product Presence Outputs: Standard outputs include a cradle relay with SPNO, 240VAC, 7A Contact and a 20 ms response time, a fast reed relay with SPNO, 240VAC, 0.5A Contacts and th 2 ms response time, and both NPN/PNP transistor outputs rated 500 mA, 45VDC, 2A peak .

The MSE-FMD95 is a direct replacement for the MCSL Model MD9100 and Model MD95100 Hot Metal Detectors. Please contact us for additional information.

 

 

Specifications

Lens F.O.V. (Field of View).
Standard: -FR2 0.5° x 25° Rectangular Slit
Optional: -FR0 0.5° x 5°, -FR1 0.5° x 15° Slit
Optional: -H2 1° Spot or -H7 7° Spot
Supply Voltage
Standard: -94 24 VDC ± 15%
Optional: -98  80 - 240 VAC, 50/60
Power Consumption
2 Watts
Sensing Element
InGaAs Photodiode
Operating Temperature
-20°C (-4°F) to +50°C (122°F) without cooling
-20°C (-4°F) to +60°C (140°F) with air cooling
to +80°C (194°F) with water cooling chilled at 20°C
Power Indication:
Blue LED of Rear Bar Display
Humidity
Max 90% RH (non condensing)
Function Indication
Top & Bottom Yellow LED's
Storage Temperature
-20°C (-4°F) to +50°C (122°F)
Min/Max I.R. Threshold Settings
Down to 270°C (5182°F) and up to 1000°C 1832°F) via programming switch
Output (#1)
Cradle Relay Output, SPNO, 240VAC, 7A with 20 ms response time.
Response Time:
1 ms min to 250 ms max via programming switch
Output (#2)
Reed Relay Output, SPNO, 240VAC, 0.5A with 2 ms response time
Remote Self-Check
Middle Yellow LED's
Outputs (#3 and #4)
PNP and NPN Transistor Output, 500 mA, 45VDC, 2A peak

Optional Output: Reed Relay Output, SPNO, 240VAC, 0.5A with 2 ms response time.

Smallest Detectable Product when utilizing a 0.5° x 25° Lens

Guideline for Temperature of Hot Product above Preset Threshold vs % of Vertical Field of View

The table below identifies the minimum % of vertical field of view required with hot steel at stated temperature for it to be repetitively detected.

Guideline for Temperature of Hot Product above Preset Threshold vs % of Vertical Field of View

Indicative Preset Thresholds
Steel Temp.
Nominal 350°C Preset Trip
Nominal 500°C Preset Trip
400°C
10%
Not Detectable
450°C
5%
100%
500°C
1%
60%
600°C
1/2%
20%
800°C
Less than 1/2%
Less than 5%

Lens Options

MSE-HMD95 is shipped as standard with 0.5° x 25° FOV Slit Rectangular Lens. Other lenses, as listed in the table below, may be chosen to accommodate the monitoring of both large and small product at close proximity or substantial distance. Even product dramatically deviating about the center of Field of View can be monitored with a slit Field of View lens arrangement.

 

Lens Options
-FR2
-CR1
-FR0
-H1
-H7
Field of View
0.5° x 25°
0.5° x 15°
0.5° x 5°
15ø
75ø
View area at 1meter (mm)
10 x 500
10 x 250
10 x 130
17ø
122ø

This interchangeability of lenses allows the user to adopt one standard sensor to suit individual installation requirements.

The MSE-FMD95 is a direct replacement for the MCSL Model MD9100 and Model MD95100 Hot Metal Detectors. Please contact us for additional information.

 

Spot Lenses

Rectangular Lenses

FOV Chart of Spot Lenses
F.O.V.
F.O.V.
D (ft)
Dia.  (in)
Dia.  (in)
D (ft)
Dia.  (in)
Dia.  (in)
0.21 ø
1.5 ø
8
1.7 ø
11.7 ø
2
0.42 ø
2.9 ø
10
2.1 ø
14.7 ø
3
0.63 ø
4.4 ø
15
3.1 ø
22 ø
4
0.8 ø
5.9 ø
20
4.2 ø
29 ø
5
1.0 ø
7.3 ø
25
5.2 ø
37 ø
6
1.3 ø
8.8 ø
30
6.3 ø
44 ø
FOV Chart of Rectangular Lenses

>
F.O.V.
0.5°
15°
25°
D (ft)
W (in)
H (in)
H (in)
H (in)
2
0.21
2.10
6.3
10.6
3
0.31
3.14
9.5
16.0
4
0.42
4.19
12.6
21.3
5
0.52
5.24
15.8
26.6
6
0.63
6.29
19.0
31.9
8
0.84
8.38
25.3
42.6
10
1.05
10.5
31.6
53.2
15
1.57
15.7
47.4
79.8
20
2.09
20.9
63.2
106.4
25
2.62
26.2
79
133
30
3.14
31.4
95
160
   
Hot Metal Detectors MSE-FMD95 Description Technical Info Housing Info Data Sheet Request More Info